久久国产亚洲欧美日韩精品,国产精品一区在线麻豆,国产拍揄自揄精品视频网站,欧美日本一区二区三区免费,无码福利视频,亚洲无码视频喷水,亚洲三级色,亚洲狠狠婷婷综合久久久久

英語實驗報告

2020-10-11 報告

  關于英語實驗報告

  Determination of heavy metals in soil byatomic absorption spectrometry(AAS)

  Name: XuFei Group: The 3rd group

  Date: Sep. 20th 2012

  Part 1 The introduction

  1.1The purposes

  (1)Learn how to operate the atomic absorption spectrometry;

  (2)Learn how to do the pretreatment of soil samples;

  (3)Get familiar with the application of atomic absorption spectrometry.

  1.2The principles

  Atomic Absorption Spectrometry (AAS) is a technique for measuring quantities of chemical elements present in environmental samples by measuring the absorbed radiation by the chemical element of interest. This is done by reading the spectra produced when thesample is excited by radiation. The atoms absorb ultraviolet or visible light and make transitions to higher energy levels .

  Atomic absorption methods measure the amount of energy in the form of photons of light that are absorbed by the sample. A detector measures the wavelengths of light transmitted by the sample, and compares them to the wavelengths which originally passed through the sample. A signal processor then integrates the changes in wavelength absorbed, which appear in the readout as peaks of energy absorption at discrete wavelengths. The energy required for an electron to leave an atom is known as ionization energy and is specific to each chemical element. When an electron moves from one energy level to another within the atom, a photon is emitted with energy E. Atoms of an element emit a characteristic spectral line. Every atom has its own distinct pattern of wavelengths at which it will absorb energy, due to the unique configuration of electrons in its outer shell. This enables the qualitative analysis of a sample.

  The concentration is calculated based on the Beer-Lambert law. Absorbance is directly proportional to the concentration of the analyte absorbed for the existing set of conditions. The concentration is usually determined from a calibration curve, obtained using standards of known concentration. Calibration Curve Method: Prepare standard solutions of at least three different concentrations, measure the absorbance of these standard solutions, and prepare a calibration curve from the values obtained. Then measure the absorbance of the test solution adjusted in concentration to a measurable range, and determine the concentration of the element from the calibration curve.

  Part 2 The materials and apparatus

  Atomic absorption spectrometry; Cu hollow cathode lamp; AC voltage stabilizer; oil-free gas compressor; acetylene cylinder; oscillator; sample boat; Erlenmeyer flask with stopper (100 ml); beaker; graduate cylinder; pipette.

  Part 3 The procedure

  3.1 operating procedure for AAS

  (1) inspect major components to ensure operating normal.

  (2) Install required hollow cathode lamp. Select “T” before turning to the power and hollow cathode lamp. Then select appropriate la mp current and preheat for 30min.

  (3) Make sure electrical meter to point to zero and then turn on high-voltage power.

  (4) Select appropriate slit width.

  (5) Rotate monochromator and select required wavelength. If the power meter is too high or low, adjust negative high voltage until the meter reads full scale.

  (6) Adjust light point and wavelength so that the meter represents the maximum value.

  (7) Turn on air compressor and acetylene gas and ignite flame. Adjust the flame appropriately and preheat the burner.

  (8) Inject distilled water into the flame and continue to preheat the burner. Inject distilled water into the flame after each sample.

  (9) Select “E”, inject blank solution into the flame and adjust the meter to zero.

  (10) Optimize analysis conditions and measure standard solution and samples.

  (11) After completion of measurement, turn off acetylene gas valve and then air compressor, cut off gas supply a moment later.

  (12) Select “T” before turning off high voltage power, decrease lamp current and then turn off the lamp. At the same time, all buttons should be on original positions.

  (13) Check the equipment before leaving the laboratory.

  3.2 Determination of soil samples

  (1) Preparation of extracting solution (0.05 mol/l EDTA solution)

  18.6 g of EDTA is dissolved with water in a beaker (500 ml). The PH is adjusted to 7.0 using dilute ammonia. The mixture is transferred into a volumetric flask (1000ml), dilute to the mark and mixed well.

  (2) Treatment of soil samples

  2.50 g of air-dried soil (60- 100 mesh) is put into an Erlenmeyer flask with stopper (100 ml). 12.5 ml of EDTA solution is added. The mixture is shaken for 1h and then filtered. The filtrate is preserved for analysis.

  (3) Preparation of Cu standard stock solution

  0.10 g of Cu is dissolved in 15 ml of (1:1) nitric acid solution. The mixture is transferred into a volumetric flask (1000 ml) and diluted to the mark with re-distilled water. The concentration of the stock standard solution is 100g/ml. (The concentration should be calculated according to the mass of Cu).The working Cu standard solution (10μg/ml) is obtained by diluting 10 ml of Cu standard stock solution to 100 ml with

  re-distilled water.

  (4) Plotting of the standard curve

  0 ml, 1 ml, 2 ml, 3 ml, 4 ml and 5 ml of Cu standard solution (10μg/ml) are added respectively to 6 volumetric flask (10 ml) with 1 ml of 5 mol/l hydrochloric acid. The mixture is diluted with re-distilled water and mixed well to give 0μg/ml, 1.00μg/ml,2.00μg/ml, 3.00μg/ml, 4.00μg/ml, 5.00μg/ml of Cu, respectively. The absorbance is measured at wavelengths of 3247 ?. The standard curve is constructed by plotting absorbance vs. concentration.

  (5) Determination of samples

  The sample solution is analyzed using the same procedure and conditions as for the standard curve. The concentration of Cu is obtained from the standard curve based on the absorbance.

  Part 4 The results

  4.1 The raw data

  4.2 AAS standard curve

  4.3 Calculation

  The absorbance of sample is 0.0511.

  According to the formula above :y=0.0446x+0.0024,R2=0.9997

  The concentration of Cu in the sample is:1.091mg/L.

  Part 5 Discussion

  In this experiment, we use the AAS to determine Cu in soil. I learn how to operate the AAS and the limitation. In the experimental process, standard solution was prepared in strict accordance with the experimental requirements and I learn how to deal with the data. Finally we get the standard curve, then, the sample concentration is calculated according to the absorbance of the sample.

  In the experiment we have nine members in our group, so we can do our best in every work we need to do. For my work, I am responsible for the preparation of solution and titration. What’s more, I learn how to use and operate the AAS on the computer later.

  Ultimately, we get the linear formula is y = 0.0446x + 0.0024 and R2=0.9997. From According to the formula and the absorbance of Cu in the sample is 0.0511, we draw the concentration of Cu in the sample is 1.091μg/ml. We have known that the concentration of test sample measured by instrument is 1.091mg/L.

  We can say our result of experiment is so very accurate from the standard curve of Cu and the value of R(R2=0.09997). The accurate data is due to the efforts of we everyone. Thanks for every members of our group.

  I have some suggestions for our experiments. Firstly when we’ll do an experiment, we must prepare our pre-lab by ourselves and translate it into Chinese .Only do like this, we can understand the experiment well. Secondly we should prefer to solute the problems in the experiment rather than ask for TA. Finally, everyone should understand his own task in the experiment.

【關于英語實驗報告】相關文章:

實驗報告范文01-20

倉儲實踐實驗報告01-13

實驗報告范文(15篇)01-20

實驗報告范文15篇01-20

實驗報告范文(集錦15篇)01-20

《血染的實驗報告》讀后感01-20

民間文學課題實驗報告01-20

《血染的實驗報告》讀后感3篇01-20

關于留學英語推薦信閱讀10-20

有關于英語推薦信閱讀10-14

運輸規劃的實驗報告 如何寫vc實驗報告
主站蜘蛛池模板: 伊人久久综在合线亚洲2019| 亚洲女人在线| 白丝美女办公室高潮喷水视频 | 亚洲无码37.| 亚洲浓毛av| 无码粉嫩虎白一线天在线观看| 综合五月天网| 国产精品黄色片| 国产午夜不卡| 欧美福利在线观看| 久久人妻xunleige无码| 亚洲欧洲日产国码无码av喷潮| 波多野结衣无码AV在线| 日本不卡视频在线| 超碰免费91| 国产爽爽视频| 日韩毛片基地| 国产欧美日韩视频怡春院| 久久久黄色片| 免费又黄又爽又猛大片午夜| 国产在线啪| 内射人妻无套中出无码| 久草网视频在线| 最新亚洲av女人的天堂| 2020精品极品国产色在线观看 | 国产精品白浆在线播放| 午夜视频在线观看区二区| 欧美无遮挡国产欧美另类| 国产毛片不卡| 国产系列在线| 久久免费视频6| 欧美日韩国产在线人| 国产一二三区在线| 亚州AV秘 一区二区三区| 日韩高清欧美| 在线亚洲精品福利网址导航| 亚洲欧美国产五月天综合| 2019国产在线| 夜精品a一区二区三区| 日韩 欧美 小说 综合网 另类| 国产亚洲现在一区二区中文| 精品视频一区二区观看| 色婷婷成人| 婷婷在线网站| 免费一级毛片| 国产成人一区在线播放| 国产亚洲视频中文字幕视频| 日韩无码真实干出血视频| 日韩一级二级三级| 在线观看国产精美视频| 亚洲AV永久无码精品古装片| 国产h视频在线观看视频| 91丨九色丨首页在线播放| 国产aaaaa一级毛片| 国产小视频免费观看| 人妻丰满熟妇αv无码| 国产综合网站| 国产91麻豆免费观看| 在线日本国产成人免费的| 伊人久久大香线蕉影院| 男人天堂亚洲天堂| 一本大道香蕉高清久久| 亚洲黄网视频| 国产精品手机在线观看你懂的| 国产成人精品一区二区三区| 蜜桃视频一区二区三区| 国产精品专区第一页在线观看| 久久久久久久久18禁秘| 久久天天躁狠狠躁夜夜躁| 99精品视频九九精品| 亚洲国产成人麻豆精品| 精品无码一区二区三区在线视频| 国产日韩精品欧美一区灰| 一本大道香蕉中文日本不卡高清二区| 国产波多野结衣中文在线播放| 久久精品娱乐亚洲领先| 国产精品亚洲一区二区三区在线观看| 99久久精品视香蕉蕉| 色网在线视频| 国产91精品调教在线播放| 国产成人亚洲精品无码电影| 久久精品亚洲热综合一区二区|